v1.0.1 (Linearization Readiness)
View this release on GitHub → Release Date: September 09, 2026
A small patch release: a new readiness signal for laser linearization, and a validation fix for ramp bandwidth.
Interface contract:
carbon-interfacev1.5.6 — unchanged from v1.0.0. Firmware compatibility: install FPGA v1.5.6 / MCU v4.1.0 with the v7.1.X bringup script / updater — unchanged from v1.0.0. Not compatible with FPGA v1.3.3 / MCU v2.6.0 or older.
New Features
is_linearization_settling(Python & C++): reports whether the sensor’s laser linearization is still converging after a configuration change, so measurement performance is not yet fully stable. Every SDL parameter change restarts linearization — wait for this to readFalsebefore trusting measurements, rather than testinghealth.ll_fom_smoothedyourself.- The visualizer shows a settling notice while linearization converges, alongside the live figure of merit and the threshold it needs to reach.
Bug Fixes
ramp_bandwidth_ghz(Python & C++ SDL configuration) now validates against the sensor’s actual supported set — 2, 4, 6, 8, or 9 GHz. Requesting any other value is rejected immediately instead of being sent to the sensor.
Documentation
For comprehensive documentation, examples, and installation instructions, visit our documentation site.
Feedback
We value your feedback! If you encounter issues or have suggestions for improvements, please see our troubleshooting guide for the best options for getting in touch with us.